Requires a security code (often found on the manual’s first page or provided by Gilbarco). Functions include:

Gilbarco SK700 fuel dispensers utilize a hierarchical command structure for programming, typically accessed via a manager keypad. 1. Programming Access and Security

Access to programming functions is divided into security levels, each requiring a specific code to prevent unauthorized changes.

Level 2 (Manager Mode): Used for common configurations like pump numbers. The standard security code is 1503.

Level 4 (Technician Mode): Required for critical parameter changes like pulse scales. The common security code is 0128. 2. Common Configuration Commands

Programming is performed using Command Codes (CC) followed by specific values.

CC 24 – Operation Mode: Defines how the dispenser communicates with the forecourt: 24 -> 1: 2-Wire 24 -> 2: Stand Alone 24 -> 3: IFSF 1.51 - LON

CC 40 – Pump Identity: Sets the pump numbers for 2-Wire communication.

CC 5 – Real-Time Display: Configures what is shown during delivery: 40.5 -> 1: Displays real-time Money. 40.5 -> 2: Displays real-time Volume.

CC 6 – Volume Pulse Scale: Sets the measurement resolution (e.g., 10, 50, or 100 pulses/litre).

CC 8 – Auto Authorization: Enables (1) or disables (2) automatic pump authorization. 3. Operational Procedures

Warm Start: To restart the dispenser or clear minor software errors without losing settings, press F1 + F2 on the Manager Keypad. Cold Start (Apollo CPU):

For a complete reset or hardware replacement, you must move the internal "CAL" switch to the left, insert a "Cold Start" link, and power up the unit. A flashing E 9 on the display confirms a successful cold start. USB Configuration: For newer Gilbarco Sk700 Programming Manual

models, you can use a special USB stick to "Get Config" (Command 8) or upload new software by inserting it and performing a cold start. 4. Error Diagnostics Errors are displayed as codes in the unit price display. E 60: Internal totalizer reset to zero.

5131: Preset keypad enabled but not detected; check connections.

5154: Printer paper out (for dispensers with integrated receipts).

For detailed step-by-step procedures, you can reference the SK700 II Programming Parameters Guide or the Installation and Commissioning Manual from Gilbarco Veeder-Root. To help you with the specific steps, could you tell me: SK700 II Programming Parameters Guide | PDF - Scribd

30 May 2008 — Set Real time Volume – Function Code 5. 40.5 -> 1 Real time Money. 40.5 -> 2 Real time Volume. 25-02.09E_ENGLISCH.DOC 30.05.2008 - SK700 II Programming Parameters Guide | PDF - Scribd

Gilbarco SK700 programming instructions are typically found within the Manager Functions Manual

or specialized service guides. Programming is generally performed using a Manager Keypad

and often requires specific security codes depending on the access level required. Core Programming Codes & Access

To enter programming mode, you typically use the following master codes on the keypad: Master Code: (frequently used for Function mode/Level 4 commands). Level 2 Security Code: (used for standard parameters like pump numbers). Key Function Codes

Programming is organized by function codes. Common configurations include: Pump Numbers: Command Code 40 in Level 2. Real-Time Volume/Money:

Function Code 5 (40.5 -> 1 for Money, 40.5 -> 2 for Volume). Pulse Scaling: Function Code 6 (e.g., 40.6 -> 100 for 100 Pulses/Liter). Auto Authorization: Function Code 8 (40.8 -> 1 to Enable). Slowdown Valve Settings: Command Code 88 (e.g., 88.1.1 for Side 1 Grade 1). Cold Start Procedure

A "Cold Start" is required for major configuration changes, such as changing the Country Code Preparation: Power down the unit and move the CAL switch to the "CAL" position. Requires a security code (often found on the

Move the two-wire enable jumper to the "Cold Start" position. The display should flash , enter code , and then press to reboot. Re-Configure:

After the reboot, basic parameters like Country Code, Pump Type, and Protocol must be set. Reference Manuals Installation & Commissioning Manual: Available at Gilbarco Australia , covering setup and initial codes. Programming Guides:

Summarized versions of parameter sets are often hosted on platforms like Technical Overview: Details on electronics and hydraulics can be found in the SK700 Technical Overview or trying to resolve a particular error code on your dispenser?

To develop or program a feature on a Gilbarco SK700 dispenser, you must access the programming mode through the manager keypad using specific security codes. Accessing Programming Mode

Most "features" or configuration settings are reached by entering the Manager Functions Initialize : Press the key on the manager keypad. Security Code : Enter the master security code, typically , then press Command Input

: The unit enters function mode (often indicated by a "0" on the display), allowing you to input specific Function Codes Common Programming Features & Function Codes

The following codes are used to configure or "develop" specific dispenser behaviors: Kentronics PPU (Price Per Unit) Settings : Used to set or change fuel prices directly at the pump. Maximum Allocation

: Set limits on the maximum volume or amount a customer can dispense in one transaction. Pulse Channel Configuration Function Code 9 : Set the start position of pulse channels (High or Low). Function Code 10

: Set the pulse format (e.g., Channel B lags Channel A by 90°). Communication Timeout Code 40.22

to adjust the PPU communications timeout (default is 10 seconds, often increased to 30 seconds for specific setups). Country Code

allows you to set the country (e.g., "36" for Australia), which automatically loads regional default configurations. This can typically only be done after a Cold Start Kentronics Advanced Feature Deployment

For more complex feature integration, such as multimedia or payment systems: USB Configuration | Step | Action | |------|--------| | 1️⃣

: On Apollo CPU boards, a special USB stick can be used to "Get Config" (Code 8) or "Send New Software" to the pump while in CRIND (Card Reader in Dispenser) : Advanced features like Gilbarco FlexPay™ Applause™ Media System

require a separate diagnostic startup menu accessed via the FlexPay EPP. Note on Safety

: Any procedure requiring internal electronics access necessitates a total electrical shut-off to the unit to prevent fire or explosion. specific feature

(e.g., price changes, pulse settings, or communication protocols) are you trying to configure or develop for the SK700? Programming SK700/SK700-2 Gilbarco | PDF - Scribd

This review assumes the reader is a fuel station owner, technician, or service provider familiar with Gilbarco’s legacy dispenser lines (the SK700 is an older, electromechanical/early electronic dispenser series).

The Gilbarco SK700 is a petroleum dispenser controller used to manage fuel dispensing, pricing, and pump functions. This programming manual covers initial setup, network and communication settings, price and product configuration, pump control parameters, security, diagnostics, and maintenance tips for technicians.


| Step | Action | |------|--------| | 1️⃣ | Connect & launch the host software (as above). | | 2️⃣ | Backup configuration. | | 3️⃣ | Go to Configuration → Nozzle Mapping. You’ll see a table: Nozzle #, Grade Code, Physical ID, Status. | | 4️⃣ | Click Add. Enter the new nozzle number, assign the correct Grade Code (e.g., “DSL” for Diesel), and set Status = Active. | | 5️⃣ | If the new nozzle is a remote (e.g., a hose from a secondary manifold), you may need to edit the I/O Mapping page to define its hardware address. | | 6️⃣ | Validate, then Upload the configuration. | | 7️⃣ | Perform a Nozzle Self‑Test from the host (Diagnostics → Nozzle Test). The software will energize the solenoid and confirm closure/opening. | | 8️⃣ | Re‑boot and confirm that the pump now displays the new grade on the affected nozzle. |


To illustrate the manual’s utility, here is a simplified workflow from the SK700 manual:

Note: Some SK700 versions require a “price lock” toggle before changes take effect. This is detailed in the manual’s “Transaction Control” section.


If you run into a specific error code (e.g., E‑104 – “Grade Not Defined”) or need a walk‑through for a less‑common function (such as configuring pre‑pay credit‑card authorizations), just let me know the exact scenario and I’ll give you a step‑by‑step guide.


Before diving into the manual itself, it's important to understand the hardware. The SK700 is an electronic dispenser control console designed for:

It manages up to 16 fueling positions (hoses), integrates with submersible pumps, handles authorization (card readers or remote POS), and logs transaction data. The programming manual is the blueprint for configuring all of these functions.