Key output panels:
| Panel | What it shows | |-------|----------------| | Pole Summary | Utilization ratio, max moment, fiber stress | | Sag-Tension Table | Final sag per span at min/max temp | | Clearance Report | Lowest point of conductor above ground, crossing clearances | | Swing Angle | Insulator deflection under wind | | Guy Tension | Load in each guy wire, anchor reaction | | GUI (Graphical User Interface) | Color-coded pole model showing load distribution | O-calc Pro Line Design
Many utilities and municipalities require stamped loading reports for joint-use permits. O-Calc Pro generates professional PDF reports that include NESC section references, input data, and clear pass/fail statuses. Key output panels: | Panel | What it
For multi-conductor bundles (e.g., two conductors per phase on 345 kV lines), O-calc Pro can simulate one sub-conductor breaking. The software calculates: This is critical for designing line armor rods
This is critical for designing line armor rods and structural resilience.